TÜRKİYE'NİN KABLO MERKEZİ!
Kategori seçiniz
  • Kategori seçiniz
  • Aluminum Power Cables
    • NA2XFGBY
    • NA2XH
    • NA2XRY
    • NA2XY
    • NAYFGBY
    • NAYR(A)Y
    • NAYRY
    • NAYY
  • Low Voltage Cables
    • H05V-K
    • H05V-U
    • H05VV-F
    • H07V-K
    • H07V-R
    • H07V-U
    • N2XFGBY
    • N2XRY
    • N2XY
    • NVV
    • NYCY
    • NYRY
    • NYY
    • YVZ3V-R
  • LSZH Cables
    • 052XZ1-F
    • H05Z1-K
    • H05Z1-U
    • H07Z1-K
    • H07Z1-R
    • H07Z1-U
    • N2XCH
    • N2XH
    • N2XH FE180
    • N2XRH
    • NHXMH
  • LSZH Cables (Cca)
    • 052XZ1-F
    • H05Z1-K
    • H05Z1-U
    • H07Z1-K
    • H07Z1-R
    • H07Z1-U
    • N2XH
    • NHXMH
  • Medium Voltage Cables
    • 2XSEYFGbY
    • 2XSY
    • A2XSEYFGbY
    • A2XSY
    • N2XSH
    • NA2XSH
  • Overhead Line Conductors
    • AAC
    • ACSR
  • Solar Cables
    • H1Z2Z2-K
WhatsApp ile Stok/Fiyat Sor
Menu
KATEGORİLER
  • Zayıf Akım Kablolar
  • ÖZNUR Kablo Fiyat ListesiPDF
  • Ana Sayfa
  • Hakkımızda
  • Tedarik
  • İletişim
WhatsApp ile Stok /Fiyat Sor
Büyütmek için tıklayın
Ana Sayfa LSZH Cables N2XH FE180 N2XH 1×6 mm² FE180 0.6/1kV XLPE – LSZH Cable
N2XH 1x4 mm² FE180 0.6/1kV XLPE - LSZH Cable
N2XH 1x4 mm² FE180 0.6/1kV XLPE - LSZH Cable
Ürünlere geri dön
N2XH 1x10 mm² FE180 0.6/1kV XLPE - LSZH Cable
N2XH 1x10 mm² FE180 0.6/1kV XLPE - LSZH Cable

N2XH 1×6 mm² FE180 0.6/1kV XLPE – LSZH Cable

The N2XH 1×6 mm² 0.6/1kV FE180 is a high-performance, halogen-free power cable designed for critical industrial installations requiring enhanced fire survivability. Manufactured in accordance with TS HD 604 S1 standards, this single-core cable features integrated mica tape and XLPE insulation to ensure reliable power transmission under extreme conditions.

  • Cable Type: N2XH Power Cable
  • Cross-Section: 1×6 mm²
  • Rated Voltage: 0.6/1 kV
  • Fire Resistance: FE180 Circuit Integrity
  • Insulation Material: XLPE with Mika Bant (Mica Tape)
  • CPR Classification: Eca
Hızlı Metraj Seçimi:
WhatsApp ile Stok/Fiyat Sor
Stok kodu: cableexport-30.1.02 Kategori: N2XH FE180 Etiketler: LSZH Cables > N2XH FE180
Paylaş:
  • Açıklama
  • Kargo & Nakliye
Açıklama

Product Overview

The N2XH 1×6 mm² 0.6/1kV FE180 is a specialized, halogen-free power cable engineered for industrial and commercial projects where safety and circuit integrity during a fire are critical. Featuring a single solid or stranded copper conductor wrapped with specialized mica tape and insulated with cross-linked polyethylene (XLPE), this cable prevents the emission of toxic gases and dense smoke. It is designed to meet strict international safety benchmarks, making it an ideal choice for global B2B procurement in environments with high human concentration and sensitive electronic infrastructure.

Key Technical Specifications

  • Conductor: One or multi-wire copper conductor
  • Cross-Sectional Area: 1×6 mm²
  • Rated Voltage (Uo/U): 0.6/1 kV
  • Insulation: XLPE (Cross-Linked Polyethylene)
  • Fire Barrier: Mica Tape (FE180 circuit integrity)
  • Outer Sheath / Characteristics: Halogen-free, flame-retardant (LSZH)
  • CPR Compliance: Eca class
Parameter Specification
Cable Designation N2XH
Conductor Size 1×6 mm²
Voltage Rating 0.6/1 kV
Insulation Compound XLPE
Special Feature FE180 Mica Tape (Halogen-Free, Flame Retardant)
Manufacturing Standard TS HD 604 S1

Applications & Installation

This halogen-free power cable is primarily utilized in fixed installations within buildings, industrial plants, power stations, and areas requiring high safety parameters against fire hazards. Thanks to its FE180 classification, it maintains circuit integrity for a specified duration during a fire event, facilitating the operation of critical emergency systems, lighting, and alarm networks. It is suitable for indoor installations in dry or damp environments, cable trays, and conduits.

Standards & Compliance

The N2XH 1×6 mm² 0.6/1kV cable is manufactured and tested in strict adherence to TS HD 604 S1 specifications. It complies with international requirements for halogen-free performance, flame propagation resistance, and low smoke density. The CPR classification is certified at Eca, ensuring full regulatory compliance for construction projects across global markets.

Kargo & Nakliye

KARGO FİRMASI SEÇİMİNDE ÖZGÜRSÜNÜZ!

Ürünü sepete ekledikten sonra not olarak kargo firmasını belirtebilirsiniz, dilediğiniz kargo firması ile gönderim yapabiliriz. Özel bir talep belirtmezseniz herhangi bir kargo firması ile gönderim yapılacaktır.

HIZLI TEDARİK ÇÖZÜMLERİ

Sizlere daha iyi ve daha hızlı hizmet sunabilmek için farklı bölgelerde ve farklı illerde çözüm ortaklarımız ile iş birliği yapmaktayız.

Sipariş vereceğiniz ürünün en kısa sürede elinize ulaşabilmesi için, size yakın olan iş ortağımız tarafından gönderim yapılacaktır.

Siparişiniz sonrası ürün veya ürünler kontrol edilir, özenle paketlenir ve kargolandığında takip etmeniz amaçlı sizlere de bilgi verilir.

Herhangi bir talep veya öneri konusunda bizler ile iletişime geçebilirsiniz.

İlgili ürünler

N2XH 7×1,5 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 1×16 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 1×35 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 1×10 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 1×185 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 1×4 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 30×2,5 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180

N2XH 1×25 mm² FE180 0.6/1kV XLPE – LSZH Cable

N2XH FE180
Adres & Telefon
E-Posta
  • Esentepe Mah. Yüzbaşı Kaya Aldoğan Sk. Onur İş Merkezi No:12 Kapı No: B01 Şişli, İstanbul, Türkiye
  • Telefon. +90 540 116 90 90
  • info@cableexport.com
WhatsApp
Hızlı iletişim
WhatsApp-Zayif-Akim
Stok ve Fiyat Sormak için
Kodu tarayın ve
WhatsApp sohbeti başlatın.
Sosyal Medya
Hesaplarımız
  • INSTAGRAM
  • FACEBOOK
  • LINKEDIN
  • X
  • THREADS
Kablo Fiyat Talebi
İstek Formu
ZAYIF AKIM KABLO 2020 Türkiye'nin Kablo Merkezi.
payments
  • KURUMSAL
  • KATEGORİLER
  • Zayıf Akım Kablolar
  • ÖZNUR Kablo Fiyat ListesiPDF
  • Ana Sayfa
  • Hakkımızda
  • Tedarik
  • İletişim
error: Content is protected !!